Performance of combustible facade systems used in green building technologies under fire
Date Issued
2021-09-01
Author(s)
Srivastava, Gaurav
Gandhi, Pravinray D.
Abstract
This book addresses fire safety of combustible fa�ade systems which has gained much attention in recent times due to several major fire accidents across the world where combustible fa�ade systems had a significant role in enhancing the growth of fire. The Grenfell tower (London) fire is one of the most severe accident in this category. The book covers basic design and functional aspects of commonly used fa�ade systems along with the materials typically used in such systems. Subsequently, it discusses the currently available testing methods at component level, intermediate level, and system level. It also provides detailed case studies of six full-scale real fire fa�ade fire experiments that have been jointly carried out by IIT Gandhinagar and Underwriters Laboratories at the full-scale fa�ade testing facility established at IIT Gandhinagar. The book will enable designers and decision makers to make better assessments regarding fire safety of existing and upcoming fa�ade systems. It also serves as a guide to deciding which testing methods are more appropriate under certain conditions.
Subjects
Fa�ade System
Green Envelop
Fa�ade Fire
Full-scale Fire Experiments
Case Studies of Fa�ade Fires
Combustible Fa�ade Systems