Repository logo
  • English
  • العربية
  • বাংলা
  • Català
  • Čeština
  • Deutsch
  • Ελληνικά
  • Español
  • Suomi
  • Français
  • Gàidhlig
  • हिंदी
  • Magyar
  • Italiano
  • Қазақ
  • Latviešu
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Српски
  • Svenska
  • Türkçe
  • Yкраї́нська
  • Tiếng Việt
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Scholalry Output
  3. Publications
  4. Ion implantation of 109Ag stable isotope as a tracer in SS316L biomedical implant for failure detection
 
  • Details

Ion implantation of 109Ag stable isotope as a tracer in SS316L biomedical implant for failure detection

Source
Materials Today Communications
Date Issued
2022-12-01
Author(s)
Malvi, Bharti
Chaudhari, Ramesh
C, Balasubramanian
Kumar, Ashutosh
K, Asokan
Das, Swagat
Paliwal, Manas
Misra, Superb K.  
DOI
10.1016/j.mtcomm.2022.104563
Volume
33
Abstract
Stainless steel alloys are widely used for biomedical applications ranging from surgical tools to biomedical implant prostheses. Apart from surgical failure, surface degradation (wear and corrosion) leading to poor osteointegration of materials are a major cause of the failure of these bioimplants. Detection of the implant failure, once it is placed inside the body, is very difficult and not so accurate. In this research, high-energy ion implantation is used to develop a tracer embedded alloy. In this novel approach, a stable isotope of silver (<sup>109</sup>Ag) is embedded as a tracer in SS316L to detect and monitor its degradation. Accelerated and normal static immersion tests were performed in 30 % H<inf>2</inf>SO<inf>4</inf> and simulated body fluid (SBF) to represent the degradation of the implant. These results show a correlation between the isotopic tracer releases with material degradation. Electrochemical corrosion tests demonstrate the ion-implanted specimens exhibit similar corrosion resistance as the bare specimens. In-vitro cytotoxicity assays indicated no significant difference between the cell viability on SS316L and <sup>109</sup>Ag ion-implanted samples. The MG-63 osteoblast cells cultured on <sup>109</sup>Ag ion-implanted SS316L show a significant enhancement in osteocalcin production compared to SS316L.
Unpaywall
URI
https://d8.irins.org/handle/IITG2025/25854
Subjects
Biological implants | Failure detection | Ion implantation | SS316L | Stable isotopes | Tracers
IITGN Knowledge Repository Developed and Managed by Library

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify