  4. A Fiber Bragg Grating-Based Sensor for Passive Cavitation Detection at MHz Frequencies
 
  • Details

A Fiber Bragg Grating-Based Sensor for Passive Cavitation Detection at MHz Frequencies

Journal
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
ISSN
08853010
Date Issued
2022-05-01
Author(s)
Jha, Chandan Kumar
Jajoria, Kuldeep
Chakraborty, Arup Lal  
Shekhar, Himanshu  
DOI
10.1109/TUFFC.2022.3161848
Abstract
Fiber Bragg gratings (FBGs) are a potential alternative to piezoelectric ultrasound sensors for applications that demand high sensitivity and immunity to electromagnetic interference (EMI). However, limited data exist on the quantitative performance characterization of FBG sensors in the MHz frequency range relevant to biomedical ultrasound. In this work, we evaluated an FBG to detect MHz-frequency ultrasound and tested the feasibility of measuring passive cavitation signals nucleated using a commercial contrast agent (SonoVue). The sensitivity, repeatability, and linearity of the measurements were assessed for ultrasound measurements at 1, 5, and 10 MHz. The bandwidth of the FBG sensor was measured and compared to that of a calibrated needle hydrophone. The FBG showed a sensitivity of 0.99, 0.769, and 0.818 V/MPa for 1, 5, and 10 MHz ultrasound, respectively. The sensor also exhibited linear response ( $0.975\leq {R}$ -Squared ≤ 0.996) and good repeatability with a coefficient of variation (CV) less than 5.5%. A 2-MHz focused transducer was used to insonify SonoVue microbubbles at a peak negative pressure of 175 kPa and passive cavitation emissions were measured, in which subharmonic and ultraharmonic spectral peaks were observed. These results demonstrate the potential of FBGs for MHz-range ultrasound applications, including passive cavitation detection (PCD).
Volume
69
Unpaywall
Sherpa Url
https://v2.sherpa.ac.uk/id/publication/3581
Subjects

Detector | fiber Brag...

Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify