Repository logo
  • English
  • العربية
  • বাংলা
  • Català
  • Čeština
  • Deutsch
  • Ελληνικά
  • Español
  • Suomi
  • Français
  • Gàidhlig
  • हिंदी
  • Magyar
  • Italiano
  • Қазақ
  • Latviešu
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Српски
  • Svenska
  • Türkçe
  • Yкраї́нська
  • Tiếng Việt
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Scholalry Output
  3. Publications
  4. Observations of the Quiet Sun during the Deepest Solar Minimum of the Past Century with Chandrayaan-2 XSM: Elemental Abundances in the Quiescent Corona
 
  • Details

Observations of the Quiet Sun during the Deepest Solar Minimum of the Past Century with Chandrayaan-2 XSM: Elemental Abundances in the Quiescent Corona

Source
Astrophysical Journal Letters
Author(s)
S.V., Vadawale, Santosh V.
B., Mondal, Biswajit
N.P.S., Mithun, Neelakandan P.S.
A., Sarkar, Aveek
P., Janardhan, Padmanabhan
B., Joshi, Bhuwan
A., Bhardwaj, Anil
M., Shanmugam, Munuswamy
A.R., Patel, Arpit R.
H.K., Adalja, Hitesh Kumar
DOI
10.3847/2041-8213/abf35d
Volume
912
Issue
1
Abstract
Elements with low first ionization potential (FIP) are known to be 3-4 times more abundant in active region loops of the solar corona than in the photosphere. There have been observations suggesting that this observed "FIP bias"may be different in other parts of the solar corona and such observations are thus important in understanding the underlying mechanism. The Solar X-ray Monitor (XSM) on board the Chandrayaan-2 mission carried out spectroscopic observations of the Sun in soft X-rays during the 2019-2020 solar minimum, considered to be the quietest solar minimum of the past century. These observations provided a unique opportunity to study soft X-ray spectra of the quiescent solar corona in the absence of any active regions. By modeling high-resolution broadband X-ray spectra from XSM, we estimate the temperature and emission measure during periods of possibly the lowest solar X-ray intensity. We find that the derived parameters remain nearly constant over time with a temperature around 2 MK, suggesting the emission is dominated by X-ray bright points. We also obtain the abundances of Mg, Al, and Si relative to H, and find that the FIP bias is ?2, lower than the values observed in active regions. � 2021 Elsevier B.V., All rights reserved.
Publication link
https://iopscience.iop.org/article/10.3847/2041-8213/abf35d/pdf
Sherpa Url
https://v2.sherpa.ac.uk/id/publication/6402
URI
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85106340017&doi=10.3847%2F2041-8213%2Fabf35d&partnerID=40&md5=7b848fbb188e6f3631b460da6adfcf85
https://d8.irins.org/handle/IITG2025/29364
IITGN Knowledge Repository Developed and Managed by Library

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify