Repository logo
  • English
  • العربية
  • বাংলা
  • Català
  • Čeština
  • Deutsch
  • Ελληνικά
  • Español
  • Suomi
  • Français
  • Gàidhlig
  • हिंदी
  • Magyar
  • Italiano
  • Қазақ
  • Latviešu
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Српски
  • Svenska
  • Türkçe
  • Yкраї́нська
  • Tiếng Việt
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Scholalry Output
  3. Publications
  4. Nonlinear seismic evaluation of confined masonry structures using equivalent truss model
 
  • Details

Nonlinear seismic evaluation of confined masonry structures using equivalent truss model

Source
Engineering Structures
ISSN
01410296
Date Issued
2021-12-01
Author(s)
Rankawat, Nikita
Brzev, Svetlana
Jain, Sudhir K.
Pérez Gavilán, Juan José
DOI
10.1016/j.engstruct.2021.113114
Volume
248
Abstract
Modern Performance-Based Design (PBD) approach for seismic analysis of building structures is based on the evaluation of nonlinear response to earthquake-induced demand and assessment of performance based on the lateral displacements/drifts. One of the key challenges associated with the application of PBD for seismic evaluation of confined masonry (CM) structures is the development of an adequate numerical model for simulating nonlinear response at different seismic demands. In this paper, an Equivalent Truss Model (ETM) has been proposed for nonlinear analysis of CM structures. The model is based on a truss analogy concept, where a CM wall is idealized as a truss consisting of pin-ended elements. A masonry panel is modelled as a compression element (strut), while horizontal and vertical reinforced concrete (RC) confining elements are modelled either as struts or tension elements (ties). ETM is essentially a macro-model that simulates nonlinear behaviour of a CM wall through lumped nonlinearity of masonry struts, while RC confining elements show linear elastic behaviour. The proposed model has been validated using the results of experimental studies on CM walls subjected to in-plane reversed cyclic loading. The paper also presents a case study, in which ETM was applied for seismic evaluation of an existing three-storey CM apartment building located in an area of moderate seismic hazard in India using nonlinear static analysis. The damage states for PBD were established based on past research studies on CM structures. A comparison of the results of conventional force-based design and PBD analyses showed that ETM can be used in conjunction with the PBD approach to evaluate existing CM buildings and also optimize design solutions for new buildings, which were developed using a conventional, force-based seismic design approach.
Unpaywall
URI
https://d8.irins.org/handle/IITG2025/25191
Subjects
Confined masonry | Equivalent truss model | Nonlinear static analysis | Performance-based design | Seismic evaluation | Shear-dominant failure mechanism | Strut-and-tie model
IITGN Knowledge Repository Developed and Managed by Library

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify