Repository logo
  • English
  • العربية
  • বাংলা
  • Català
  • Čeština
  • Deutsch
  • Ελληνικά
  • Español
  • Suomi
  • Français
  • Gàidhlig
  • हिंदी
  • Magyar
  • Italiano
  • Қазақ
  • Latviešu
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Српски
  • Svenska
  • Türkçe
  • Yкраї́нська
  • Tiếng Việt
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Scholalry Output
  3. Publications
  4. A Rotor-Tied DFIG Scheme With One Phase Open Circuit Fault-Tolerant Capability
 
  • Details

A Rotor-Tied DFIG Scheme With One Phase Open Circuit Fault-Tolerant Capability

Source
IEEE Transactions on Industrial Electronics
ISSN
02780046
Date Issued
2025-01-01
Author(s)
Chakraborty, Soham
Chakrabarti, Abanishwar
Maiti, Dipten
Mukhopadhyay, Susovan
Biswas, Sujit K.
DOI
10.1109/TIE.2024.3468729
Volume
72
Issue
5
Abstract
This article proposes a fault-tolerant control scheme for a transformer isolated three-phase rotor-tied doubly fed induction generator (RT-DFIG) suitable for grid connected wind energy conversion system (WECS). The scheme uses back-to-back connected three-phase four-wire two-level converters having a common dc bus with the grid side converter (GSC) connected to the point of common coupling via a delta/star/star isolation transformer whose neutral is joined to the dc bus midpoint. The stator side converter (SSC) is coupled to the star connected stator terminals of the RT-DFIG with the stator neutral joined to the dc bus midpoint. The rotor is connected directly to the grid via the other star winding of the isolation transformer. This fault-tolerant topology along with the control scheme restrict negative sequence current and allows circulation of zero sequence current through the neutral wire via the dc bus midpoint. This enables seamless operation with time-invariant power transfer and balanced grid side line currents during one-phase open-circuit fault in either the GSC or SSC or one phase of transformer secondary or line reactors or one phase of RT-DFIG stator. This proposed scheme uses a simple control without any extra hardware and hence is cost-effective. Simulation and experimental results are provided to validate the proposed concept.
Unpaywall
URI
https://d8.irins.org/handle/IITG2025/28416
Subjects
Delta/star/star transformer | open circuit fault-tolerant operation (FTO) | rotor-tied doubly fed induction generator (RT-DFIG) | wind energy conversion system (WECS)
IITGN Knowledge Repository Developed and Managed by Library

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify