Repository logo
  • English
  • العربية
  • বাংলা
  • Català
  • Čeština
  • Deutsch
  • Ελληνικά
  • Español
  • Suomi
  • Français
  • Gàidhlig
  • हिंदी
  • Magyar
  • Italiano
  • Қазақ
  • Latviešu
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Српски
  • Svenska
  • Türkçe
  • Yкраї́нська
  • Tiếng Việt
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Scholalry Output
  3. Publications
  4. Pulsed Ultrasound Assisted Thermo-Therapy for Subsurface Tumor Ablation: A Numerical Investigation
 
  • Details

Pulsed Ultrasound Assisted Thermo-Therapy for Subsurface Tumor Ablation: A Numerical Investigation

Source
Journal of Thermal Science and Engineering Applications
ISSN
19485085
Date Issued
2021-08-01
Author(s)
Singh, Gajendra
Paul, Abhijit
Shekhar, Himanshu  
Paul, Anup
DOI
10.1115/1.4048674
Volume
13
Issue
4
Abstract
High-intensity focused ultrasound (HIFU) is a promising therapy for thermal ablation and hyperthermia, characterized by its non-invasiveness and high penetration depth. Effective HIFU thermo-Therapy requires the ability to accurately predict temperature elevation and corresponding thermal dose distribution in target tissues. We report a parametric numerical study of the thermal response and corresponding of thermal dose in a soft tissue in response to ultrasound. We compared the predictions of tissue models with two, three, and seven layers, to ultrasound-induced heating at duty cycles ranging from 0.6 and 0.9. Further, two tumor sizes and transducer powers (10 W and 15 W) were considered. The inhomogeneous Helmholtz equation was coupled with the Pennes bio-heat equation to predict heating in response to pulsed ultrasound. Necrotic lesion size was calculated using the cumulative equivalent minute (CEM) thermal dose function. In-vitro experiments were performed with agar-based tissue phantoms as a preliminary validation of the numerical results. The simulations conducted with the seven-layered model predicted up to 33.5% lower peak pressure amplitude than the three-layered model. As the ultrasound pulse width decreased with the equivalent sonication time fixed, the corresponding magnitude of the peak temperature and the rate of temperature rise decreased. Pulsed ultrasound resulted in the increased volume of necrotic lesions for an equivalent time of sonication. The findings of this study highlight the dependence of HIFU-induced heating on target geometry and acoustic properties and could help guide the choice of suitable ultrasound exposure parameters for further studies.
Publication link
https://arxiv.org/pdf/2007.05158
URI
https://d8.irins.org/handle/IITG2025/25349
Subjects
duty cycle | high-intensity focused ultrasound | multi-layered tissue | thermal lesion
IITGN Knowledge Repository Developed and Managed by Library

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify